Alpha’s standby battery offering incorporates Gel for thermal dissipation to ensure optimal life performance for your particular Broadband application. The AlphaCell batteries provide the longest runtimes and the best longevity in today’s demanding outdoor non-temperature controlled cable power environments. All backed with industry leading full non-prorated warranties.

GXL and GOLD-HP:

  • High-performance Silver Alloy for maximum life expectancy
  • Increased runtime for VoIP networks
  • 100% runtime capacity out-of-box – No cycling required
  • Maintenance-free threaded inserts — no periodic retorquing

Technische Daten

 

General Specifications
Model: 215 GOLD-HP 190 GOLD-HP 210 GXL 180 GXL 165 GXL
Warranty1: 5 to 6 year 4
full replacement
5 to 6 year 4
full replacement
4 to 5 year
full replacement
4 to 5 year
full replacement
4 to 5 year
full replacement
Service Life: Extended Extended Extended Extended Extended
Runtime (minutes)2: 215 190 210 180 165
Sealed VRLA: Valve regulated lead acid Valve regulated lead acid Valve regulated lead acid Valve regulated lead acid Valve regulated lead acid
Heat Resistant: Extreme Extreme High High High
Hydrogen Emission: Low Low Low Low Low
Terminals: Threaded insert
1/4” - 20 UNC
Threaded insert
1/4” - 20 UNC
Threaded insert
1/4” - 20 UNC
Threaded insert
1/4” - 20 UNC
Threaded insert
1/4” - 20 UNC
Cells Per Unit: 6 6 6 6 6
Voltage Per Unit: 12.8 12.8 12.8 12.8 12.8
Conductance Value: 1175 1100 1175 1100 1000
Max. Discharge Current (A): 900 900 900 900 900
Short Circuit Current (A): 2800 2600 2800 2600 2500
10 Second Volts @ 100A: 11.4 11.3 11.4 11.3 11.2
Ohms Impedance 60Hz: 0.0050 0.0050 0.0050 0.0050 0.0055
Capacity at 20hrs: (to 1.75VPC) 107Ah 95Ah 106Ah 94Ah 86Ah
BCI Group Size: 31 31 31 31  
Weight (lb/kg): 72/32.7 66/30 72/32.7 66/30 63/28.6
Height w/ Terminals (in/mm): 8.48/215.4 8.48/215.4 8.48/215.4 8.48/215.4 8.05/204.5
Width (in/mm)3: 13.42/340.9 13.42/340.9 13.42/340.9 13.42/340.9 12.5/317.8
Depth (in/mm)3: 6.80/172.7 6.80/172.7 6.80/172.7 6.80/172.7 6.83/173.4
Operating Temperature Range
Discharge:
-40 to 71°C (-40 to 160°F)
Charge (with temp compensation): -23 to 60°C (-9.4 to 140°F)
Float Charging Voltage (VDC): 13.5 to 13.8 13.5 to 13.8 13.5 to 13.8 13.5 to 13.8 13.5 to 13.8
AC Ripple Charger: 0.5% RMS or 1.5% of fl oat charge voltage recommended for best results. Max. allowed = 4% P-P

Notes:
1 Warranty varies by country and region. Warranty valid only when used with Alpha approved Power Supplies, Chargers and Enclosures. Consult your sales person for details.
2 Runtimes calculated using a 25A DC constant current load with voltage discharge to 1.75V/cell @ 25°C.
3 Dimensions at top of battery.
4 In Canada, the Gold warranty is 6 years when AlphaGuardTM Charge Management is used in the battery string, and 5 years if AlphaGuard Charge Management is not used.