Total Power Solutions
Our catalogues

Our catalogues

German    English    French
Flexnet Fiber UPS

Flexnet Fiber UPS

Element Powering - 48VDC 300W UPS

Flexnet Fiber UPS
Data sheet
Downloads
Source of supply

Alpha introduces a cost effective UPS powering solution for today’s distributed communications networks. Designed to provide battery backup power where needed in the field, the FlexNet FiberUPS can supply power to telephony, fiber-to-the-curb or home (FTTC/H), or other communication equipment requiring 48VDC to operate. Installed in a pole, wall, or ground mount weather resistant enclosure, the FlexNet FiberUPS will keep field distributed electronics up and running during power disturbances and outages. The FlexNet products can be an inexpensive solution to provide dedicated power to optical nodes.

  • Power modules can be used in a variety of Alpha enclosures
  • Rugged 48VDC UPS for outdoor or indoor applications
  • Temperature compensated battery charging for extended battery life
  • Visual and electrical indicators for on-site and remote reporting
  • Flexible cabinet mounting

Variants Technical data


Nominal Specifications
Input
Voltage Range: 85 to 170 or 132 to 264VAC selectable
Frequency: 50 or 60Hz
Output
Voltage: 48VDC (42 to 54VDC)
Output Power Max.: 300W
Transfer Characteristics: Uninterrupted output
DC Ripple: 500mV
Battery
String Voltage: 48VDC
Typical Capacity: Four 50Ah (85GXL)
Type: Sealed lead acid GEL, maintenance free
Battery Charging: Temperature compensated
Backup Time Approx.: 8hrs @ 275W load
Mechanical
Battery Type: Maintenance free, leak-proof, sealed VRLA (valve regulated lead acid)
Dimensions  
(in): 6H x 10.1W x 3.25D
(mm) 152H x 256.5W x 82.6D
Weight (lb/kg): 10/4.5
Environment
Operating Temperature: -40 to 65°C (-40 to 149°F)
Storage Temperature: -50 to 70°C (-58 to 158°F)
Humidity: 0 to 95% non-condensing
LED Indicators
OUTPUT okay (green)
STANDBY operation (green blinking)
LOW/MISSING BATTERY (red blinking)
REPLACE BATTERY (red)
Alarm Indicators
AC FAIL (TELM 1)
Replace Battery (TELM 2)
Battery Missing (TELM 3)
Battery Low (TELM 4)

Note: Compliant with PacketCable™ UPS Specifications
Embedded MTA Primary Line Support Specification
(PKT-SP-EMTA-Primary-101-001128)
Mounting Configuration
Bracket mounted inside enclosure
Agency Compliance
FCC part 15 Class B
CSA–NRTL\C (CSA950)
Standard Features
No Audible Noise
Reverse Battery Polarity Protection